Interactive 3D Roof
Your roof, from every angle.
Rotate the shingle roof, separate its layers and select a component to see how the system fits together.
“Commit thy works unto the LORD, and thy thoughts shall be established.”
— Proverbs 16:3
Explore the roof from the deck up.
Rotate the model or choose a component to explore the roof.
Loading the interactive roof. Component explanations are available below.
More views and controls
Drag to rotate. Pinch or scroll to zoom. Use More views for keyboard controls.
Vented-attic shingle system. Choose ridge or box ventilation to compare exhaust options.
1 of 11
Sheathing / OSB
The structural deck beneath the roofing
OSB means oriented strand board: wood strands bonded into structural panels. Plywood is another wood-panel option. The deck supports the roofing layers; rafters or trusses support the deck.
Aerial measurement cannot establish concealed deck condition. Panel rating, thickness, support and attachment need review for the actual structure.
Understand hidden decking conditionsPeel-and-stick underlayment
A bonded secondary line of water protection
BHR uses full-deck peel-and-stick on asphalt-shingle replacements. The blue layer represents this self-adhered membrane over the prepared deck. Its release liner is removed so the adhesive can bond to a suitable substrate. Connected laps and transitions help keep water above the deck if the covering is damaged.
Florida heat, wind-driven rain and storms make this protection useful. A suitable membrane can seal around correctly driven nails; it cannot fix poor flashing, wet decking or an incompatible assembly. The shingle guide compares the underlayment options.
Compare underlayment approachesStarter shingles
The first course beneath the field shingles
Atlas Pro-Cut HP42 starter shingles come in wrapped bundles, like field shingles. The full shingle separates at its perforation into starter strips. They sit beneath the first field course at the eave and, where specified, the rake, providing the designed edge seal. The dark perimeter strip marks this location.
A starter roll is a different accessory and format. Do not assume an upside-down field shingle or another starter product matches the selected system.
Field shingles
The overlapping weather surface
Field shingles cover the main roof planes in overlapping courses. The offsets, exposure and attachment work as a system, carrying water down the slope. This example shows dimensional asphalt shingles.
Field shingles differ from starters and hip/ridge caps. Metal, tile and low-slope roofs use different materials and installation details.
Hip & ridge shingles
Caps finish the roof intersections
Purpose-made caps overlap across the horizontal ridge or an outward-sloping hip. Where a shingle-over ridge vent is used, the compatible cap sits above that vent. Ridge caps finish the peak shown here; hip caps serve the outward-sloping intersections on a hip roof.
Caps are roofing, not the ventilation opening itself. Their shape, length of attachment and compatibility need to suit the selected roof and vent.
Chimney flashing
Connected metal where roof meets masonry
The chimney example combines an apron on the downslope face, stepped side flashing integrated with shingle courses, an upslope water-diversion detail and counterflashing over the base flashing. These pieces direct water around the interruption.
A bead of sealant alone does not replace the layered connection. Chimney geometry, masonry condition and the approved assembly determine the actual detail.
Pipe vents & boots
A transition around a plumbing pipe
The pipe lets the plumbing system vent; the boot is the roof connection around it. Options include formed lead flashing or a compatible metal flange with a rubber collar. Lead is formed around the pipe with a termination suited to that product; the upper flange connects into the roofing layers. The shingle roofing section includes separate boot examples.
A plumbing pipe is not an attic exhaust or a duct hood. Lead and rubber-collar boots have different details and maintenance needs. The collar, flange and connection all need inspection when tracing a leak.
Explore pipe boots and edge colorsDrip edge
A defined edge for shedding water
This narrow metal flashing protects the exposed roof edge and helps direct water away from underlying materials. BHR offers gray, brown, black or white edge-metal colors. Gold only highlights its location at the eave and rake in this teaching model; it is not the selected finish.
Drip edge, fascia, soffit and gutter are different parts. Lap relationships, metal dimensions and fastening depend on the edge and approved assembly.
Explore pipe boots and edge colorsRidge vent & airflow
Intake and exhaust serve a vented attic together
A ridge vent, such as Atlas TruRidge All-Weather, sits beneath compatible ridge-cap shingles. Soffit intake near the eaves supplies outside air, with a clear channel past insulation into the vented attic. Follow the airflow drawing in the shingle guide for a closer look.
Ventilation needs a design, not simply more openings. Vent attachment must reach the required deck penetration through the cap and vent; ordinary field-shingle nail length is not automatically suitable. Ridge and box/off-ridge exhausts are alternatives.
See how attic airflow worksOff-ridge / box vent
Static attic exhaust on the roof slope
Box vent and off-ridge vent are grouped here as one static attic-exhaust component. The single slant-back hood shown sits below the ridge over a roof-deck opening. Compact and wider twin-hood products are variations of this category, with their own sizes and capacities. Selecting it shows this exhaust instead of the ridge vent.
Outside air enters through soffit intake and travels into the attic before leaving through the selected high exhaust. A box/off-ridge vent is not a plumbing boot or duct hood. The layout and net free vent area must suit the attic; adding competing exhaust types is not a substitute for a ventilation design.
See how attic airflow worksGRV / gooseneck
A weather hood for a connected duct
A gooseneck is a curved, downward-facing hood over a duct outlet. Its flange connects into the roofing layers. Hoods come in different sizes, including 4-inch and 10-inch models, to match the duct and equipment.
Galvanized and Galvalume steel have different protective coatings. Duct size, damper, screen and collar must suit the connected equipment and the selected product.